When I get asked “What thickness PIR insulation do I need for my roof?” I never give a one-size-fits-all answer. After 12 years as a PIR insulation supplier, I’ve seen too many customers cut corners and end up with higher energy bills, condensation issues, or even structural damage because they guessed at thickness instead of doing the right math. Let’s break this down like I do with every new builder, renovator, and homeowner who walks through my door. PIR Insulation

First, let’s get clear on what PIR actually does. Polyisocyanurate (PIR) is a rigid foam insulation with some of the highest thermal resistance (that’s R-value, the number you see on product labels) per inch of any common insulation. Unlike mineral wool or fiberglass, which are fluffy and can leave gaps if installed wrong, PIR panels have a consistent, closed-cell structure that traps heat really well. But all that performance only matters if you pick the right thickness for your specific roof.
The biggest mistake I see is people assuming “thicker = better.” While it’s true that a thicker panel will have a higher R-value, there are practical limits—space in your roof cavity, budget, and building regulations. The UK (and most of Europe) has set minimum standards for new builds, and even for older renovations, meeting those standards will save you money on heating for decades. Let’s start with the basics: what kind of roof are we working with? That’s the first question I ask every customer.
There are three main roof types people use PIR for: flat roofs, pitched (sloped) roofs, and cold roofs. Each has different needs.
For flat roofs, this is where PIR really shines because it’s rigid, so it doesn’t sag like other insulation. If it’s a new build flat roof, the current minimum U-value (which is the inverse of R-value, measuring how much heat escapes) required by UK building regulations is 0.18 W/m²K. To hit that, you usually need between 150mm and 200mm of PIR. Wait, let’s do the math: PIR typically has an R-value of around 3.5 per inch. So 150mm is about 6 inches, which would be 6 x 3.5 = 21 R-value. 200mm is about 8 inches, 28 R-value. A U-value of 0.18 lines up with that R-range. But if your flat roof is a renovation—say you’re re-roofing an old garage—you might not have the depth for 200mm, so we can work with 120mm, which gives around 17 R-value, enough to hit 0.22 U-value, which is acceptable for most domestic renovations if you’re also sealing any gaps.
Pitched roofs are trickier because there are two main ways to install PIR here: between the rafters (internal) or under the rafters (over the top, sometimes called a warm roof conversion). If you’re going between the rafters, the depth of the rafters will dictate how thick you can go. Most standard rafters are 150mm deep, so you can fit a 140mm PIR panel with a 10mm gap for ventilation. That gives you around 24.5 R-value, which hits the 0.18 U-value minimum for new builds. If your rafters are deeper—say 200mm—you can go up to 190mm, for a much higher 33.25 R-value, which is great if you live in a colder area or want to future-proof your home for energy price hikes.
Cold roofs are the ones with a ventilated gap between the insulation and the roof tiles, right? If you have an old cold roof, adding PIR on top of the existing rafters is often the best upgrade path. For that, again, 150mm to 200mm is standard. I had a customer last year who renovated a 1970s bungalow with a pitched cold roof. He wanted to cut costs, so he bought 100mm PIR and tried to fit it over the rafters. His energy bills dropped only 10% instead of the 30% he was expecting, and in the winter, he noticed ice dams forming on his eaves—because his insulation wasn’t thick enough to stop heat from escaping and melting the snow on the roof. That’s the kind of mistake I see all the time.
Now, let’s talk about U-value vs R-value, because a lot of people mix these up. R-value is resistance to heat flow; higher = better. U-value is heat transfer, lower = better. Building regulations set minimum U-values depending on where you are and what the roof is being used for. For a domestic roof in England, Wales, and Northern Ireland, the current Approved Document L requires a minimum U-value of 0.16 W/m²K for new pitched roofs, and 0.18 for flat roofs. Wait, that’s a tweak from a few years back. So to hit that 0.16 U-value for a pitched roof, you actually need around 170mm of PIR, which is about 6.7 inches, giving ~29.75 R-value. That’s why when a customer says “I want 150mm,” I explain that while that works for older regulations, it might not meet the current standards, and if you’re selling your home in 10 years, you might have to upgrade it anyway.
But it’s not just regulations. Your location matters too. If you live in the north of Scotland, where winters are much colder and wind chill is higher, you might want to go 200mm or even 250mm of PIR, even if the regulations only require 150mm. A customer in Inverness told me last year that adding 200mm of PIR cut his heating bills by almost 40%—way more than he expected—because he was losing so much heat through his old roof before. If you live in the south of England, you might get away with the minimum, but adding an extra 20mm won’t add that much to your cost, and it’ll mean you’re prepared for any future changes to building codes or energy costs.
Another factor is roof type: is your roof a warm roof or a cold roof? Warm roofs, where the insulation is on top of the waterproof membrane, are more efficient, and the PIR thickness here is calculated differently. For a warm flat roof, the total thickness of insulation (usually PIR) needs to account for the load from the roof itself, any foot traffic if it’s a roof terrace, and the drainage. If it’s a non-trafficable flat roof, 120mm to 150mm works, but if you’re turning it into a roof garden or a patio, you’ll need to add a layer of protection on top, and maybe go up to 200mm to compensate for the load. That’s a point a lot of people miss—if their flat roof is going to be used for anything beyond just a roof, they need thicker PIR.
Wait, let’s also address some common myths. I get asked all the time: “Can I use thinner PIR and add another layer later?” Technically, yes, but PIR panels are designed to be installed as a single layer (or two layers offset to avoid gaps) because joining layers can create thermal bridges. If you install a 100mm layer now and add 50mm later, there will be a joint where the two layers meet, and that’s a spot where heat can escape. It’s better to get the right thickness first than to try and add on later, which will end up costing you more in the long run.
Another myth: “PIR is the same as EPS or XPS.” No, EPS (expanded polystyrene) has an R-value of around 3 per inch, XPS is around 4 per inch, so PIR is better. That means you can get the same R-value with less PIR than you would with the others. For example, to get 28 R-value, you’d need 7 inches of PIR, 9.3 inches of XPS, or 10 inches of EPS. So PIR is not just more efficient, it takes up less space, which is a big deal if your roof has a tight cavity. If you’re working on a small extension where space is limited, PIR is the way to go.
I always tell customers to do a simple check before they buy: measure the depth of their rafters or the space they have in their flat roof, multiply the maximum depth by 0.8 (leaving 20mm for ventilation, unless it’s a warm roof), and that gives you a rough maximum thickness to work with. For example, 150mm rafters x 0.8 = 120mm, so you can’t go thicker than that without modifying your rafters. Wait, but modifying rafters is an option, right? A lot of people don’t want to spend money on new rafters, but if you can add an extra 20mm, going from 120mm to 140mm, that’s a huge jump in performance for not much extra cost.
Let’s go back to that customer I mentioned earlier, the one who bought 100mm PIR for his pitched roof. He had 150mm rafters, so he could have fit 120mm, but he went cheaper. The issue wasn’t just the energy bill—he had a condensation problem in his loft because his insulation wasn’t thick enough to keep the loft at a consistent temperature. Condensation can lead to mould, which is bad for your health, and it can rot the wood in your rafters over time. That’s why I always prioritize getting the right thickness over saving a few pounds upfront.
So let’s sum up the numbers I usually give customers, based on common scenarios:
- New build flat roof: 150-200mm PIR, to hit 0.18-0.16 U-value
- Renovation flat roof (non-trafficable): 120-150mm PIR, if space is limited
- New pitched roof (between rafters): 150-170mm PIR, matching rafter depth
- Renovation pitched roof (over rafters): 150-200mm PIR, for maximum efficiency
- Cold roof conversion: 150-200mm PIR, depending on location
But wait, what if you’re going for a super-insulated home, like a Passivhaus? Then you might need up to 300mm of PIR. Passivhaus requires a U-value of around 0.1 W/m²K, which would need a lot more insulation, and PIR is perfect for that because it’s high-performance, so you don’t have to fill your entire roof cavity with thick, fluffy insulation that would take up space in your living areas.
Another thing to consider is the type of PIR insulation. Not all PIR is the same—some have a facer that’s better for moisture resistance, which is important for roofs, and some are more flexible, but for roof applications, you want rigid PIR with an aluminium facer, because that adds another layer of protection against heat loss and moisture. Thickness is only half the battle; the quality of the panel matters too, which is why I only supply PIR that meets British Standards, so you know you’re getting consistent R-value across every panel.
I get a lot of people who come to me after buying cheap PIR from a online retailer, and they’re disappointed because the R-value is lower than advertised. That’s why I always tell them to check the product’s declared R-value, not the manufacturer’s claimed value. British Standards require manufacturers to test and declare the actual R-value, so if a panel says R-21, that’s what you get, not some inflated number. That’s why when you’re calculating thickness, use the declared R-value per inch, not a rough estimate. For example, if a panel has a declared R-value of 3.2 per inch, then 150mm (6 inches) would be 19.2 R-value, so you’d need 7 inches (175mm) to hit 22.4 R-value, which gets you closer to the 0.16 U-value.
Let me also talk about installation, because even the perfect thickness is useless if it’s installed wrong. PIR panels need to be tightly butted together, no gaps, because gaps are thermal bridges. If you have gaps between panels, you’re losing as much heat as if you had thinner insulation. So when you’re choosing thickness, make sure the panels fit perfectly into your roof cavity, no need to cut them too tight (but not too loose either). For pitched roofs between rafters, it’s best to have panels that are slightly smaller than the rafter depth, so you can leave a 10mm gap for ventilation, which prevents condensation.
I had a customer last year who tried to install his own PIR for his garage flat roof. He bought 100mm panels, cut them to fit, but left a 20mm gap in the middle because he couldn’t get the cuts right. His garage is always cold, even in summer, and his energy bill for the attached house went up 15% because the cold air from the garage was seeping into the house. If he’d spent an extra £50 on 120mm panels that fit perfectly, he wouldn’t have had that problem.
So, to answer the original question: “What thickness PIR insulation do I need for my roof?” The short answer is: it depends on your roof type, your location, building regulations, your budget, and how much you want to save on energy. The long answer is: take the time to measure your space, check the regulations for your area, factor in your climate, and don’t cut corners on thickness or quality.
If you’re still not sure, that’s what I’m here for. I’ve worked with thousands of customers over the years, from DIY homeowners to large construction companies, and I can help you calculate exactly how much PIR you need, what thickness is right, and even guide you on installation tips to make sure it’s done correctly. Don’t guess—get the right information first, because the money you save on heating over the life of your home will be way more than the cost of the insulation.

If you’d like to discuss your specific roof project, want a custom recommendation, or have questions about PIR insulation products, feel free to get in touch. We’re here to help you make the best choice for your home.
XPS References
- Approved Document L: Conservation of Fuel and Power, UK Government (2021)
- British Standard EN 13165: Thermal insulation products for buildings – Factory made rigid polyurethane (PUR) and polyisocyanurate (PIR) insulation products – Specification
- Energy Saving Trust: Roof Insulation Guide (2023)
- Passivhaus Trust: UK Passivhaus Standard Requirements (2022)
- The Insulation Manufacturers Association: PIR Insulation Performance Guidelines (2022)